Hypersil phenyl column
WebColumn Format: Analytical Column: Diameter (Metric) 4.6 mm: For Use With: HPLC: Length (Metric) 30 mm: Max. Pressure: 5800 psi (400 bar) Particle Size: 3 μm: pH: 2 to … WebNova-Pak Phenyl Column, 60Å, 4 µm, 3.9 mm X 150 mm, 1/pk. Leverage the phenyl ligand in the Nova-Pak HP Phenyl column to achieve unique compound selectivity with reversed-phase applications. The Waters Nova-Pak HP Phenyl column series is based on 4 µm silica-based particle technology. Available in the 4 µm and 6 µm particle sizes, the ...
Hypersil phenyl column
Did you know?
WebHypersil™ BDS phenyl columns offer alternative selectively to Hypersil™ BDS C18 and C8 columns and phenyl phases offer clear advantages over alkyl chains when the … WebFor a robust, general-purpose column, use Thermo Scientific™ Hypersil BDS C18 columns.Chromatography columns separate molecules within mixtures during gas or liquid chromatography. Filled with stationary phase compositions or chemical compounds, the prepacked options reduce the preparing time required. The vertical pieces are able to …
Web4 jul. 2024 · Acclaim 120 C18, Hypersil. ODS (C18), BetaSil C18 Nucleosil C18, Nucleodur C18 Partisil ODS Inertsil ODS. Pinnacle C18, Viva C18, Allure. C18, Ultra C18 Capcell Pak C18. other dimensions available, please compare particle size and pore size WebThe store will not work correctly in the case when cookies are disabled.
WebHPLC Columns. Bare Silica; Reversed Phases; Normal Phases; Ion Exchange Phases; HPLC Guard Cartridges. Bare Silica; Reversed-phases; Normal Phases; Ion Exchange … WebHypersil Gold Aq (100 mm × 1 mm; 1.9 μm) T: 5°C. A: H 2 O + 0.02% FA. B: ACN + 0.02% FA. 0.15: Acquity ... In this sense, in addition to the lipophilic interactions offered by C18 columns, phenyl columns provide a different selectivity thanks to the π−π interactions between the electron-rich double bonds ...
Web液相色谱专用词培训终.ppt,液相色谱专用词培训终 第一页,共二十六页,2024年,8月28日 液相色谱分离原理 * * a+b+c 液体流动相 c b a c b a c b a c b c 当流动相中携带的混合物流经固定相时,其与固定相发生相互作用 由于混合物中各组分在性质和结构上的差异,与固定相之间产生的作用力的大小、强弱不 ...
WebHPLC Column BDS-HYPERSIL-C18 250x4mm 5µm, Manufacturer: Thermo Fisher Scientific, Column Description: Hypersil BDS C18 (RP18, ODS, Octadecyl), Pore Size: 130 ... おむすびママWebThe F s factor describes the similarity of two columns. A small F s indicates that two columns are very similar. A large F s factor indicates that two columns are very … おむすびと 鮭Webage than most C18 columns for sharp peak shapes of non-polar and moderately polar compounds. c18 ODS, RP-18, LC18, Octadecyl Si C 18 H 37 Classic reversed phase material. ... Zorbax SB-Phenyl Spher. 1.8, 3.5, 5 80 — 180 5.5 — No Zorbax SB-CN Spher. 1.8, 3.5, 5 80 — 180 4 — No おむすびの日WebHypersil™ Phenyl-BDS HPLC Columns Catalog number: 28905-154630 Related applications: Chromatography Technical Support Customer Service As a base … park bologna aeroportoWebGenesis 4um Phenyl Column 150x3.9 mm: GENESIS: HICHFM15980E: Genesis 4um Phenyl Column 150x4.6mm: GENESIS: HICHFM25980E: Genesis 4um Phenyl Column 250x4.6mm: GENESIS: HICHFH1961-2/N: Genesis 4um Silica Guard (for 3.0 - 4.6mm id columns) 3pk: GENESIS: HICHFM25961E: Genesis 4um Silica Column 250x4.6mm: おむすび 人材WebStep #2 (optional): Select F s Weighting Factors : The F s factor describes the similarity of two columns. A small F s indicates that two columns are very similar. A large F s factor indicates that two columns are very different. It is calculated according to the following equation: where: H 1 - H 2 is the difference between the hydrophobicity parameters of … おむすび三昧Web390 Hypersil BDS Phenyl Columns Exceptional stability and alternative selectivity to C18 and C8 columns ` High quality, base deactivated columns ` Unique selectivity for aromatic and slightly polar compounds ` Manufactured under ISO 9001:2000 conditions Other column dimensions are available. おむすびまん